Dongguan Ampfort Electronics Co., Ltd.

Smart Circuit Protection Experts Around You

Manufacturer from China
Verified Supplier
4 Years
Home / Products / Ceramic Cartridge Fuse /

SEV SEVI Polarity Nonpolarity High Voltage DC Contactor 10A 20A 30A 50A 100A 150A 200A 250A 300A For Electric Vehicle

Contact Now
Dongguan Ampfort Electronics Co., Ltd.
Visit Website
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:MrJames Lai
Contact Now

SEV SEVI Polarity Nonpolarity High Voltage DC Contactor 10A 20A 30A 50A 100A 150A 200A 250A 300A For Electric Vehicle

Ask Latest Price
Video Channel
Brand Name :AMPFORT
Model Number :SEV10/SEVI10
Certification :CCC number 2019010304167727
Place of Origin :Dongguan,China
MOQ :50pcs
Price :Negotiable
Payment Terms :T/T
Supply Ability :30000000 Piece/Pieces per Month
Delivery Time :10 workdays
Packaging Details :Bulk
Name :High Voltage DC Contactor
Implementation criteria :GB/T 14048.4-2010
Coil voltage :12VDC and 24VDC
Circuit rated current :10A
Coil terminal length :A:390mm ; B:150mm
Application :Electronic Equipment
Color :White
Lead Type :Wire Leads
Package :Bulk
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

SEV SEVI Polarity Nonpolarity High Voltage DC Contactor 10A 20A 30A 50A 100A 150A 200A 250A 300A For Electric Vehicle

Product Features

1.Full seal construction and high safety

2.Coil voltage:12VDC and 24VDC

3.Small size and high switching power

4. Full sealed inside by epoxy encapsulation technology to insure coil and contactor against being oxidized for long time

5.Use permanent magnet to eliminate electrica arc,high reliability

6. Implementation criteria:GB/T 14048.4-2010

7. Certification: CCC number 2019010304167727

Application

Mainly used in high voltage main circuit,pre-charge circuit,slow charging circuit,fast charging circuit,high voltage auxiliary system of electromobile,as well as high voltage main circuit system in charging pile,power control system of wind power,photovoltaic

Outline And Dimensions

Coil Operating Voltage

Item Norminal Voltage 12VDC 24VDC
1 Max. Voltage 16VDC 28VDC
2 Max Pickup(close) Voltage 9VDC 18VDC
3 Min Dropout(open) Voltage 1.0VDC 2.0VDC
4 Coil Current 267mA 133mA
5 Coil Power(20℃) 3.5W 3.5W
6 Coil Resistance(20℃) ±5% Ohm 45 180

Peformance Parameter

Type Parameters Unit Values

Main

contactor

Contact Arrangement,Main Contacts / 1 Form X(SPST NO DM)
Rated Operating Voltage VDC 12-1000
Overcurrent A 20A 180S/30A 120S
Break Current at 320VDC A 100,1 Cycle
Contact Resistance, Typ.(@10A) mOhm ≤5
Dielectric Withstanding Voltage VAC 2500,(5mA,60s)
Insulation Resistor @1000VDC MOhm ≥100
Life Load life 10A/450V Cycle 7*104
Load life 10A/750V 2*103
Load life 10A/1000V 103
Mechanical Life Cycle 2*106
Pick up/Release Close(includes bounce),Typ. ms 20
Release(includes arcing),Max ms 5
Environment Shock,11ms,1/2 Sine,Peak,operating G 50
Vibration,Sine,80-2000Hz,Peak G 20
Operating Ambient Temperature -40 ~ +85
Weight,Norminal g ≤105

Product life estimated(Make/Break):

Product life estimated(Make/Break) curve under resistive load

Continuous current range

Use Precautions Of High Voltage DC Contactors

1. Contacts with the polarity of contactor,please operate according to the product identification promp.

2. Do not use fallen products.

3.Avoid installing products in strong magnetic fields(near transformers or magnets) or near objects with thermal radiation.

4. The product with energy saver has a reverse surge absorber circuit,so there is no need to use surge protector.
5.About 0.1 seconds after the product with energy saving board is connected to the power supply,the circuit starts to switch automatically.Do not turn off repeatedly at the same position,otherwise the contactor energy saving board may be damaged.
6. About the load life: This contactor is a high voltage DC switch,please do not exceed its switching ability and life parameters in the state of use,otherwise may lose the ability to cut off.Please replace if necessary.
7. If the coil and contacts of the contactor are continuously connected to the rated voltage(or current),the power supply is cut off and then switched on immediately,then the resistance of the coil will increase as the temperature of the coil increases,thus increasing the pick-up voltage of the product and possibly leading to excess of the rated suction voltage.In this case,the follwing measures should be taken: such as reducing the load current,limiting the duration of power on or using coil voltage higher than the rated pick-up voltage.
7. If the coil and contacts of the contactor are continuously connected to the rated voltage(or current),the power supply is cut off and then switched on immediately,then the resistance of the coil will increase as the temperature of the coil increases,thus increasing the pick-up voltage of the product and possibly leading to excess of the rated suction voltage.In this case,the follwing measures should be taken: such as reducing the load current,limiting the duration of power on or using coil voltage higher than the rated pick-up voltage.